Description
The ProbeSeq Hepatitis B Virus (HBV) LAMP Primer Set is a ready-to-use six-primer system engineered for fluorescence-based loop-mediated isothermal amplification (LAMP) targeting conserved genomic regions of HBV. This product supports research-use molecular detection, assay development, and rapid prototyping of isothermal amplification platforms.
Hepatitis B Virus remains a major global health concern and a key target in molecular diagnostics research, particularly in efforts to develop rapid and decentralized nucleic acid detection systems. LAMP enables amplification at a constant temperature, simplifying instrumentation and reducing time-to-result compared to conventional PCR workflows. Reliable amplification performance depends heavily on primer architecture; this primer set has been structured to promote stable amplification kinetics and consistent fluorescence signal generation while minimizing non-specific amplification artifacts.
What’s Included
Each set contains a complete LAMP primer architecture:
-
F3 and B3 outer primers
-
FIP and BIP inner primers
-
LF and LB loop primers
Primers are individually labeled and supplied with sequence documentation for traceability and research integration.
Target Strategy
The primer system targets a conserved region of the HBV genome selected for:
-
Broad genotype coverage
-
Minimal homology to human genomic sequences
-
Reduced risk of non-specific amplification
Target selection prioritizes robustness and compatibility with fluorescence-based detection workflows.
Product Format
Available in two configurations:
Lyophilized format
• Delivered dry for enhanced stability
• Reconstitute in nuclease-free water or preferred buffer
Solution format
• 100 µM stock concentration per primer
• Supplied in nuclease-free water or TE buffer
Standard packaging supports approximately 100–200 reactions depending on reaction volume and optimization parameters. Custom bulk quantities are available for larger research or device-development programs.
Performance Orientation
Designed for compatibility with fluorescence-based LAMP workflows, including:
-
Intercalating dye fluorescence monitoring
-
Real-time isothermal-capable instruments
-
Portable fluorescence readers
-
Microfluidic and cartridge-integrated systems
Typical reaction temperature range: 60–65 °C. Primer ratios follow standard LAMP architecture; optimization may be required depending on enzyme system and reaction chemistry.
Quality Control
Each batch undergoes:
-
Sequence verification
-
Mass confirmation
-
Concentration validation
-
Manufacturing quality control review
Certificate of Analysis (CoA) available upon request.
Storage
Store at –20 °C.
Lyophilized primers are stable for up to 12 months under recommended storage conditions.
Avoid repeated freeze–thaw cycles for solution format.
Applications
-
HBV molecular detection research
-
Rapid isothermal assay development
-
Blood-borne pathogen research panels
-
Point-of-care testing platform prototyping
-
Biosensor and microfluidic integration studies
Important Notice
For Research Use Only (RUO).
Not intended for diagnostic, therapeutic, or clinical applications.